Junolane MotionPLC中文

Single-Axis Home

RESET_AXIS · V4.23

Home one selected X, Y, Z or R axis using single-stage or three-stage mode. Speed selection is separate from this motion command.

Requires multi-axis interpolation mode.

Hexadecimal notation is used for IDs, indexes, modes and sentinel values where applicable. Physical quantities (such as pulses, milliseconds and pulse/s) remain in their native units. Macro names are shown only when defined by the firmware.

Input parameters

ParameterInitial valueMeaning
Axis / targetaxisXSelected X, Y, Z or R axis. The operating mode must support coordinate axes.
Homing modehome_mode0x01U1 searches only; 2 searches, releases and latches. Both use the selected axis profile. 0x01U = MTGM_OP_HOME_MODE_SINGLE_STAGE; 0x02U = MTGM_OP_HOME_MODE_THREE_STAGE.

Initial values are editor defaults for a newly inserted instruction; configure them for the actual machine.

Firmware macro definitions

Hexadecimal equivalents of the firmware definitions; numeric values are unchanged.

#define MTGM_OP_HOME_MODE_SINGLE_STAGE 0x01U
#define MTGM_OP_HOME_MODE_THREE_STAGE 0x02U

Execution and usage

← Back to instruction treeFull user manual (PDF)