Move one coordinate axis to an absolute pulse position.

Requires multi-axis interpolation mode.

Hexadecimal notation is used for IDs, indexes, modes and sentinel values where applicable. Physical quantities (such as pulses, milliseconds and pulse/s) remain in their native units. Macro names are shown only when defined by the firmware.

Input parameters

ParameterInitial valueMeaning
Axis / targetaxisXSelected X, Y, Z or R axis. The operating mode must support coordinate axes.
Pulse count / coordinatepulse_count0Target/increment for coordinate moves, or fixed-pulse quantity in RUN_MOTOR.
Compensation IDcompensation_idNo compensation (0xFFFFFFFFUL)MCU compensation ID 0x00000000UL to 0x00000007UL; 0xFFFFFFFFUL disables compensation. Verify the source and current result. MTGM_OP_COMPENSATION_NONE = 0xFFFFFFFFUL.

Initial values are editor defaults for a newly inserted instruction; configure them for the actual machine.

Firmware macro definitions

Hexadecimal equivalents of the firmware definitions; numeric values are unchanged.

#define MTGM_OP_COMPENSATION_NONE 0xFFFFFFFFUL